Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.316
Filtrar
1.
Cir. Esp. (Ed. impr.) ; 101(11): 746-754, Noviembre 2023. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-227082

RESUMO

Introducción El nivel de recomendación del abordaje robótico en la cirugía hepática es controvertido. Se realiza un análisis descriptivo, retrospectivo yunicéntrico de los resultados a corto plazo de la cirugía hepática robótica y laparoscópica en un mismo periodo.MétodosAnálisis descriptivo del abordaje robótico y laparoscópico sobre 220 resecciones en 182 pacientes sometidos a cirugía hepática mínimamente invasiva.ResultadosEntre abril de 2018 y junio de 2022 se realizaron 92 resecciones hepáticas robóticas (RHR) en 83 pacientes y 128 laparoscópicas (RHL) en 99 pacientes. Se observaron más resecciones mayores (p<0,001) y más resecciones múltiples (p=0,002) en el grupo CHL. El porcentaje de resecciones anatómicas fue similar (RHR: 64,1 vs. RHL: 56,3%). En el grupo CHL el tiempo medio operatorio fue de 212min (DE: 52,1), las pérdidas hemáticas de 276,5ml (100-1.000) y la tasa de conversión del 12,1%. La estancia media hospitalaria fue de 5,7 días (DE: 4,9), la morbilidad fue del 27,3%, con un 2% de mortalidad. En el grupo CHR el tiempo medio operatorio fue de 217min (DE: 53,6), las pérdidas hemáticas fueron de 169,5ml (100-900) y la tasa de conversión del 2,5%. La estancia media hospitalaria fue de 4,1 días (DE: 2,1) y la morbilidad fue del 15%, con mortalidad nula.ConclusiónLa cirugía mínimamente invasiva hepática es una técnica segura y reproducible. La CHR permite realizar resecciones hepáticas con seguridad y parece ser una técnica no inferior a la CHL, pero para determinar el abordaje mínimamente invasivo de elección en cirugía hepática se requieren estudios aleatorizados. (AU)


Introduction The level of recommendation of the robotic approach in liver surgery is controversial. The objective of the study is to carry out a single-center retrospective descriptive analysis of the short-term results of the robotic and laparoscopic approach in liver surgery during the same period.MethodsDescriptive analysis of the short-term results of the robotic and laparoscopic approach on 220 resections in 182 patients undergoing minimally invasive liver surgery.ResultsBetween April 2018 and June 2022, a total of 92 robotic liver resections (RLR) were performed in 83 patients and 128 laparoscopic (LLR) in 99 patients. The LLR group showed a higher proportion of major surgery (P<.001) and multiple resections (P=.002). The two groups were similar in anatomical resections (RLR 64.1% vs. LLR 56.3%). In the LLS group, the average operating time was 212min (SD 52.1). Blood loss was 276.5ml (100-1000) and conversion 12.1%. Mean hospital stay was 5.7 (SD 4.9) days. Morbidity was 27.3% and 2% mortality. In the RLS group, the mean operative time was 217min (SD 53.6), blood loss 169.5ml (100.900), and conversion 2.5%. Mean hospital stay was 4.1 (SD 2.1) days. Morbidity was 15%, with no mortality.ConclusionMinimally invasive liver surgery is a safe technique, and in particular, RLS allows liver resections to be performed safely and reproducibly; it appears to be a non-inferior technique to LLS, but randomized studies are needed to determine the minimally invasive approach of choice in liver surgery. (AU)


Assuntos
Humanos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/instrumentação , Laparoscopia , Epidemiologia Descritiva , Estudos Retrospectivos , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação
3.
IEEE J Transl Eng Health Med ; 10: 2500410, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35774413

RESUMO

Minimally invasive surgery (MIS) incorporates surgical instruments through small incisions to perform procedures. Despite the potential advantages of MIS, the lack of tactile sensation and haptic feedback due to the indirect contact between the surgeon's hands and the tissues restricts sensing the strength of applied forces or obtaining information about the biomechanical properties of tissues under operation. Accordingly, there is a crucial need for intelligent systems to provide an artificial tactile sensation to MIS surgeons and trainees. This study evaluates the potential of our proposed real-time grasping forces and deformation angles feedback to assist surgeons in detecting tissues' stiffness. A prototype was developed using a standard laparoscopic grasper integrated with a force-sensitive resistor on one grasping jaw and a tunneling magneto-resistor on the handle's joint to measure the grasping force and the jaws' opening angle, respectively. The sensors' data are analyzed using a microcontroller, and the output is displayed on a small screen and saved to a log file. This integrated system was evaluated by running multiple grasp-release tests using both elastomeric and biological tissue samples, in which the average force-to-angle-change ratio precisely resembled the stiffness of grasped samples. Another feature is the detection of hidden lumps by palpation, looking for sudden variations in the measured stiffness. In experiments, the real-time grasping feedback helped enhance the surgeons' sorting accuracy of testing models based on their stiffness. The developed tool demonstrated a great potential for low-cost tactile sensing in MIS procedures, with room for future improvements. Significance: The proposed method can contribute to MIS by assessing stiffness, detecting hidden lumps, preventing excessive forces during operation, and reducing the learning curve for trainees.


Assuntos
Laparoscopia/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Instrumentos Cirúrgicos/classificação , Desenho de Equipamento , Tato
4.
Lasers Surg Med ; 54(6): 841-850, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35419820

RESUMO

OBJECTIVES: Photothermal therapy (PTT) is a minimally invasive or noninvasive method by destructing cancer cells through selective thermal decomposition. However, a long period of laser irradiation to achieve coagulative necrosis often causes unfavorable thermal damage to the surrounding healthy tissue. The current study aims to evaluate the feasibility of temporal power modulation to improve the treatment efficacy of gold nanorods-assisted PTT against tumor tissue. MATERIALS AND METHODS: A total of 25 µg/ml of PEGylated gold nanorods (PEG-GNR) was used as an absorbing agent during 1064 nm laser irradiation for PTT. Temperature monitoring was conducted on the aqueous solution of PEG-GNR for dosimetry comparison. For in vivo tests, CT-26 tumor-bearing murine models with PEG-GNR injected were treated with three irradiation conditions: 3 W/cm2 for 90 s, 1.5 W/cm2 for 180 s, and 3 W/cm2 for 60 s followed by 1.5 W/cm2 for 60 s (modulated). Ten days after the treatments, histology analysis was performed to assess the extent of coagulation necrosis in the treated tissues. RESULTS: The temporal power modulation maintained the tissue temperature of around 50°C for a longer period during the irradiation. Histology analysis confirmed that the modulated group entailed a larger coagulative necrosis area with less thermal damage to the peripheral tissue, compared to the other irradiation conditions. CONCLUSION: Therefore, the power-modulated PTT could improve treatment efficacy with reduced injury by maintaining the constant tissue temperature. Further studies will examine the feasibility of the proposed technique in large animal models in terms of acute and chronic tissue responses and treatment margin for clinical translations.


Assuntos
Ouro , Nanotubos , Neoplasias/terapia , Fototerapia/métodos , Animais , Linhagem Celular Tumoral , Estudos de Viabilidade , Ouro/uso terapêutico , Lasers , Camundongos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Necrose , Fototerapia/instrumentação
5.
Int J Med Robot ; 18(4): e2392, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35368139

RESUMO

BACKGROUND: In minimally invasive surgery (MIS), instruments pass through trocars which are installed through the incision points. This forms a fulcrum effect and imposes significant constraint. For robotic manipulative operations, the real-time trocar information is a prerequisite. Systems acquire this knowledge either with a prior registration procedure or through coordinated control of their joints. METHODS: A robust and real-time trocar identification algorithm based on least square (LS) algorithm was proposed in the context of human-robot co-manipulation scenario. RESULTS: Both in vitro and in vivo experiments were performed to verify the effectiveness of the proposed algorithm. The estimated trocar coordinates expressed in the robot base frame were further leveraged to implement an instrument gravity compensation function. CONCLUSIONS: An LS based approach can be employed to robustly estimate the real-time trocar information so as to implement more practical robotic functions.


Assuntos
Procedimentos Cirúrgicos Robóticos , Algoritmos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Instrumentos Cirúrgicos
7.
Med Sci Monit ; 28: e934985, 2022 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-34996886

RESUMO

BACKGROUND Oblique lateral interbody fusion (OLIF) is a new and minimally invasive surgery. This study aimed to compare the clinical efficacy and safety of oblique lateral interbody fusion with anterolateral screw fixation and with posterior percutaneous screw fixation in treating single-segment mild degenerative lumbar diseases. MATERIAL AND METHODS A retrospective analysis was performed on 51 patients with single-segment mild degenerative lumbar diseases who received OLIF from April 2017 to January 2020 in Hong Hui Hospital, Xi'an Jiao Tong University; 24 and 27 patients received OLIF with anterolateral screw fixation (OLIF+AF) and OLIF with posterior percutaneous screw fixation (OLIF+PF), respectively. Anesthesia time, operation time, intraoperative blood loss, intraoperative fluoroscopy number, hospital stay, postoperative complications, Visual Analog Scale (VAS) score, Oswestry Disability Index (ODI) score, anterior and posterior disc heights, foraminal height, and fusion rate of the 2 groups were compared to assess clinical and radiological outcomes. RESULTS Anesthesia time, operation time, intraoperative blood loss, number of intraoperative fluoroscopy, and VAS score in the OLIF+AF group were significantly better than those in the OLIF+PF group (P<0.05). There were no significant differences in ODI score, anterior and posterior disc heights, foraminal height, fusion rate, and incidence of complications between the 2 groups (P<0.05). CONCLUSIONS OLIF+AF in treating single-segment mild degenerative lumbar diseases produces a satisfactory clinical effect. Moreover, OLIF+AF does not invade the paraspinal muscle group, thereby reducing trauma, postoperative residual low back pain, operation time, bleeding, and frequency of fluoroscopy. Thus, OLIF+AF is a feasible treatment method for single-segment mild degenerative lumbar diseases.


Assuntos
Degeneração do Disco Intervertebral , Dor Lombar , Vértebras Lombares , Dispositivos de Fixação Ortopédica/classificação , Complicações Pós-Operatórias , Fusão Vertebral , China/epidemiologia , Feminino , Humanos , Degeneração do Disco Intervertebral/diagnóstico , Degeneração do Disco Intervertebral/epidemiologia , Degeneração do Disco Intervertebral/cirurgia , Dor Lombar/diagnóstico , Dor Lombar/etiologia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Seleção de Pacientes , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Radiografia/métodos , Índice de Gravidade de Doença , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Resultado do Tratamento , Escala Visual Analógica
9.
World Neurosurg ; 157: 160-161, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34688938

RESUMO

The authors present the case of a 52-year-old male with a history of new-onset seizures who presented in status epilepticus. Computed tomography and magnetic resonance imaging demonstrated an olfactory groove mass. A keyhole supraorbital-eyebrow approach assisted with a microinspection tool was performed for tumor resection.1-5 A Simpson grade 2 tumor resection was achieved, and histopathology revealed a World Health Organization grade I olfactory groove meningioma. Postoperative and follow-up course has been unremarkable, with early postoperative imaging demonstrating no residual tumoral mass. The operative video highlights the advantages of using the microinspection tool for the visualization of deep lesions.


Assuntos
Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Neuroendoscopia/métodos , Fossa Craniana Anterior/cirurgia , Sobrancelhas , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Neuroendoscopia/instrumentação
10.
Dis Colon Rectum ; 65(3): e184-e190, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34856590

RESUMO

BACKGROUND: We describe a natural orifice technique for simultaneous endoluminal lateral suspension of apical vaginal wall and rectal prolapse fixation with ultrasound and fluoroscopic assistance. IMPACT OF INNOVATION: The technique is minimally invasive, can be performed under regional anaesthesia, and avoids laparotomy or use of a mesh in addition to preserving the uterus. TECHNOLOGY MATERIALS AND METHODS: This technique involves suprapubic transvaginal ventral suture colposuspension, fixation of the anterior rectal wall to the undersurface of the anterior abdominal wall and tack fixation of the posterior rectal wall to the underlying sacral promontory through a submucosal tunnel performed endoscopically with fluoroscopic and ultrasound assistance. PRELIMINARY RESULTS: Seven patients with a mean age of 63 years were followed between 3 to 11 months. CONCLUSIONS: This is a novel minimally invasive transluminal procedure that repairs concomitant rectal and vaginal prolapse in the same sitting. FUTURE DIRECTIONS: Improvement in the instrument design and incorporation of endoluminal robotic systems will enhance the technical ease. The study needs validation in larger series of patients with longer follow-up.


Assuntos
Anestesia por Condução/métodos , Cirurgia Endoscópica por Orifício Natural , Prolapso Retal , Prolapso Uterino , Estudos de Viabilidade , Feminino , Fluoroscopia/métodos , Humanos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Cirurgia Endoscópica por Orifício Natural/métodos , Melhoria de Qualidade , Prolapso Retal/diagnóstico por imagem , Prolapso Retal/cirurgia , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Assistida por Computador/métodos , Dispositivos de Fixação Cirúrgica , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos , Prolapso Uterino/diagnóstico por imagem , Prolapso Uterino/cirurgia
11.
Biomed Res Int ; 2021: 7739628, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34840980

RESUMO

BACKGROUND: To know the clinical value of mammotome-assisted minimally invasive resection (MAMIR) in the treatment of patients with breast neoplasm, we performed a retrospective clinical study for the patients treated with the MAMIR and conventional open resection (COR). METHODS: Postoperative complications were compared between 40 patients treated with the MAMIR and 40 patients treated with the COR. The postoperative complications mainly included intraoperative blood loss, hospitalization days, operative time, surgical scar, and incidence of postoperative complications. RESULTS: We found that the amount of intraoperative blood loss, hospitalization days, operative time, surgical scar, and incidence of postoperative complications in the MAMIR group were significantly lower than those of patients in the COR group. CONCLUSION: Our results indicated that patients with breast neoplasm treated with the MAMIR had better outcomes, which reinforced the advantage of this approach.


Assuntos
Neoplasias da Mama/cirurgia , Mastectomia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Adulto , Neoplasias da Mama/diagnóstico por imagem , Cicatriz/etiologia , Feminino , Humanos , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Tempo de Internação , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia Mamária/instrumentação , Ultrassonografia Mamária/métodos
12.
Med Sci Monit ; 27: e931389, 2021 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-34615847

RESUMO

BACKGROUND Trigger finger is a very common disorder that occurs in both adults and children. Trigger finger presents mainly as pain and limited movement of the affected digit. This report describes a modified percutaneous needle release and an evaluation of its clinical efficacy to treat trigger thumb. MATERIAL AND METHODS Trigger thumb of 11 patients was released percutaneously using a specially designed needle (0.8×100 mm) with a planus tip. Complete release was ensured when no more grating sound was heard and the needle moved freely at the tip. Pain-related functional score was evaluated preoperatively and at 3 months postoperatively. Resolution of Notta's node, triggered or locked, Quinnell's criteria, and patient satisfaction were also assessed at 3 months after the operation. RESULTS After the percutaneous trigger thumb release, the overall visual analog scale (VAS) and pain-related functional scores declined significantly (P<0.01). There was no recurrence of thumb locking or triggering or Notta's node. Only the first patient had incomplete release of the first annular pulley, and all patients showed high satisfaction with the procedure at 3 months after their operation. During the study, patients did not experience any complications such as inflammation, edema, or digital nerve injury. CONCLUSIONS This study demonstrated that the percutaneous technique is effective, less time-consuming, and safe for treating trigger thumb. Our release technique using a specially designed percutaneous needle is a valuable treatment for trigger thumb.


Assuntos
Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Agulhas , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/métodos , Dedo em Gatilho/cirurgia , Adulto , Idoso , Seguimentos , Humanos , Pessoa de Meia-Idade , Dor/etiologia , Dor/cirurgia , Medição da Dor/métodos , Satisfação do Paciente/estatística & dados numéricos , Recuperação de Função Fisiológica , Estudos Retrospectivos , Resultado do Tratamento , Dedo em Gatilho/complicações
13.
World Neurosurg ; 156: e57-e63, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34492389

RESUMO

BACKGROUND: Minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) is one of several approaches to lumbar interbody fusion that has proven to be a safe and effective treatment for symptomatic lumbar degenerative disease The clinical outcomes of MIS-TLIF are generally favorable, but there is still controversy regarding its ability to restore sagittal alignment. For this reason, expandable transforaminal lumbar interbody fusion cages have been developed and designed to improve ability to restore disc height and segmental lordosis. The use of expandable cages in transforaminal lumbar interbody fusion has increased drastically; however, it is not clear how effective cage expansion is in regard to disc space lordosis, distraction, and long-term outcome. METHODS: We reviewed a cohort of patients with symptomatic lumbar degenerative disc pathology who underwent MIS-TLIF at our institution. We compared clinical and radiographic outcomes of expandable versus nonexpandable cage use in MIS-TLIF focusing on mean changes in segmental lordosis, disc height, and postoperative complications. The results were compared with other studies reported in the international literature. RESULTS: Mean change in segmental lordosis was not significantly different between the 2 groups. A significantly higher rate of postoperative subsidence was demonstrated in the expandable cage group. CONCLUSION: This study established that expandable cage use in single-level transforaminal lumbar interbody fusion did not reduce the rate of postoperative complications, but rather significantly increased a patient's risk of postoperative subsidence. Expandable cages do not presently demonstrate improved clinical outcomes or improved sagittal alignment compared with static cages.


Assuntos
Fixadores Internos , Lordose/cirurgia , Vértebras Lombares/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Complicações Pós-Operatórias/etiologia , Fusão Vertebral/métodos , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Fixadores Internos/efeitos adversos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Lordose/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Resultado do Tratamento
14.
J Gynecol Obstet Hum Reprod ; 50(10): 102211, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34481135

RESUMO

Gynecologic oncologists had originally preferred minimally invasive surgery (MIS) over laparotomic surgery for patients with early-stage cervical cancer until the Laparoscopic Approach to Cervical Cancer (LACC) trial reported a worse prognosis and more loco-regional recurrence in patients treated with MIS. Although some controversy remains, experts suggested that tumor cell spillage and aggravation may have been caused by intra-corporeal colpotomy, usage of uterine elevators, maintenance of Trendelenburg position, and tumor irritation by capnoperitoneum during surgery. Thus, we introduce a surgical procedure with some steps added to the conventional MIS radical hysterectomy for preventing tumor spillage during the surgery, which is currently being evaluated in terms of safety and efficacy through a prospective, multicenter, single-arm, phase II study, entitled "Safety of laparoscopic or robotic radical surgery using endoscopic stapler for inhibiting tumor spillage of cervical neoplasms (SOLUTION trial: NCT04370496)".


Assuntos
Histerectomia/métodos , Neoplasias do Colo do Útero/cirurgia , Adulto , Endoscopia/instrumentação , Endoscopia/métodos , Feminino , Humanos , Histerectomia/instrumentação , Histerectomia/estatística & dados numéricos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/estatística & dados numéricos , Neoplasias , Estudos Prospectivos , Grampeadores Cirúrgicos , Neoplasias do Colo do Útero/complicações , Hemorragia Uterina/diagnóstico , Hemorragia Uterina/cirurgia
15.
Adv Sci (Weinh) ; 8(18): e2101290, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34272935

RESUMO

Minimally invasive robotic surgery often requires functional tools that can change their compliance to adapt to the environment and surgical needs. This paper proposes a submillimeter continuous variable stiffness catheter equipped with a phase-change alloy that has a high stiffness variation in its different states, allowing for rapid compliance control. Variable stiffness is achieved through a variable phase boundary in the alloy due to a controlled radial temperature gradient. This catheter can be safely navigated in its soft state and rigidified to the required stiffness during operation to apply a desired force at the tip. The maximal contact force that the catheter applies to tissue can be continuously modified by a factor of 400 (≈20 mN-8 N). The catheter is equipped with a magnet and a micro-gripper to perform a fully robotic ophthalmic minimally invasive surgery on an eye phantom by means of an electromagnetic navigation system.


Assuntos
Cateteres , Desenho de Equipamento/métodos , Fenômenos Mecânicos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Oftalmológicos/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Ligas , Fenômenos Eletromagnéticos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Imagens de Fantasmas , Procedimentos Cirúrgicos Robóticos/métodos
16.
J Cardiothorac Surg ; 16(1): 182, 2021 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-34167559

RESUMO

BACKGROUND: The timing for heart surgery following cerebral embolization after cardiac valve vegetation is vital to postoperative recovery being uneventful, additionally Covid-19 may negatively affect the outcome. Minimally invasive methods and upgraded surgical instruments maximize the benefits of surgery also in complex cardiac revision cases with substantial perioperative risk. CASE PRESENTATION: A 68 y.o. patient, 10 years after previous sternotomy for OPCAB was referred to cardiac surgery on the 10th postoperative day after neurosurgical intervention for intracerebral bleeding with suspected mitral valve endocarditis. Mitral valve vegetation, tricuspid valve insufficiency and coronary stenosis were diagnosed and treated by minimally invasive revision cardiac surgery on the 14th postoperative day after neurosurgery. CONCLUSION: The present clinical case demonstrates for the first time that the minimally invasive approach via right anterior mini-thoracotomy can be safely used for concomitant complex mitral valve reconstruction, tricuspid valve repair and aorto-coronary bypass surgery, even as a revision procedure in the presence of florid endocarditis after recent neurosurgical intervention. The Covid-19 pandemic and prophylactic patient isolation slow down the efficacy of pulmonary weaning and mobilisation and prolong the need for ICU treatment, without adversely affecting long-term outcome.


Assuntos
Ponte de Artéria Coronária/métodos , Estenose Coronária/cirurgia , Endocardite/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Cirurgia Vídeoassistida/métodos , Idoso , COVID-19/epidemiologia , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/instrumentação , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Pandemias , Complicações Pós-Operatórias , Reoperação , SARS-CoV-2 , Toracotomia/efeitos adversos , Toracotomia/instrumentação , Toracotomia/métodos , Cirurgia Vídeoassistida/efeitos adversos
17.
J Clin Neurosci ; 89: 97-102, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34119302

RESUMO

Brain retraction is a necessary yet potentially damaging requirement of accessing lesions located in deep structures. The development of minimally-invasive tubular retractors (MITRs) provides the theoretical advantage of maximizing visualization of and access to deep-seated lesions, all while minimizing collateral tissue damage. These advantages make MITRs preferable to traditional bladed retractors in the majority of deep-seated lesions. Several commercially-available MITR systems currently exist and have been shown to aid in achieving excellent outcomes with acceptable safety profiles. Nevertheless, important drawbacks to currently-available MITR systems exist. Continued pursuit of an ideal MITR system that provides maximal visualization and access to deep-seated lesions while minimizing retraction-related tissue damage is therefore important. In this review, we discuss the historical development of MITRs, the advantages of MITRs compared to traditional bladed retractors, and opportunities to improve the development of prospective MITRs.


Assuntos
Encéfalo/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Neurocirúrgicos/instrumentação , História do Século XX , História do Século XXI , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/história , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Neurocirúrgicos/história , Procedimentos Neurocirúrgicos/métodos
18.
World Neurosurg ; 152: e101-e111, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34033952

RESUMO

BACKGROUND: Minimally invasive surgical techniques have resulted in improved patient outcomes. One drawback has been the increased reliance on fluoroscopy and subsequent exposure to ionizing radiation. We have previously shown the efficacy of a novel instrument tracking system in cadaveric and preliminary clinical studies for commonplace orthopedic and spine procedures. In the present study, we examined the radiation and operative time using a novel instrument tracking system compared with standard C-arm fluoroscopy for patients undergoing minimally invasive lumbar fusion. METHODS: The radiation emitted, number of radiographs taken, and time required to complete 2 tasks were recorded between the instrument tracking systems and conventional C-arm fluoroscopy. The studied tasks included placement of the initial dilator through Kambin's triangle during percutaneous lumbar interbody fusion and placement of pedicle screws during both percutaneous lumbar interbody fusion and minimally invasive transforaminal lumbar interbody fusion with or without instrument tracking. RESULTS: A total of 23 patients were included in the analysis encompassing 31 total levels. For the task of placing the initial dilator into Kambin's triangle, an average of 4.21 minutes (2.4 vs. 6.6 minutes; P = 0.002), 15 fluoroscopic images (5.4 vs. 20.5; P = 0.002), and 8.14 mGy (3.3 vs. 11.4; P = 0.011) were saved by instrument tracking. For pedicle screw insertion, an average of 5.69 minutes (3.97 vs. 9.67; P < 0.001), 14 radiographs (6.53 vs. 20.62; P < 0.001), and 7.89 mGy (2.98 vs. 10.87 mGy; P < 0.001) were saved per screw insertion. CONCLUSIONS: Instrument tracking, when used for minimally invasive lumbar fusion, leads to significant reductions in radiation and operative time compared with conventional fluoroscopy.


Assuntos
Fluoroscopia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Neuronavegação/métodos , Duração da Cirurgia , Exposição à Radiação/prevenção & controle , Fusão Vertebral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Neuronavegação/instrumentação , Parafusos Pediculares , Estudos Prospectivos , Fusão Vertebral/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
19.
Medicine (Baltimore) ; 100(21): e26148, 2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34032769

RESUMO

RATIONALE: Redo surgeries after mitral valve repair are technically demanding. Procedures applying the NeoChord device (NeoChord Inc, St. Louis Park, MN) have proven to be safe and feasible in selected patients requiring mitral valve repair due to a leaflet prolapse or flail. However, its use for redo procedures after conventional surgical repair has not been well established yet. PATIENT CONCERNS: We report the case of a 57-year-old man who presented with dyspnea upon exertion. The patient had undergone a minimally invasive surgical mitral valve repair because of a flail leaflet of the segments segment 2 of the posterior mitral valve leaflet (P2)/segment 3 of the posterior mitral valve leaflet (P3) 4 years before. DIAGNOSES: Transesophageal echocardiography identified a relapse of severe mitral valve regurgitation. The recurring regurgitant jet was caused by a flail leaflet due to newly ruptured native chords. INTERVENTIONS: After discussion in an interdisciplinary heart team, we performed a minimally invasive off-pump redo procedure applying the NeoChord device under three-dimensional transesophageal echocardiographic guidance. OUTCOMES: The echocardiographic result with only trivial residual mitral regurgitation as well as the further clinical course of the patient were favorable. LESSONS: As redo surgery after minimally invasive mitral valve repair is challenging, the NeoChord device represents a novel treatment option that does not require cardiopulmonary bypass.


Assuntos
Cordas Tendinosas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Insuficiência da Valva Mitral/cirurgia , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Insuficiência da Valva Mitral/diagnóstico por imagem , Recidiva , Reoperação
20.
Sci Robot ; 6(50)2021 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-34043580

RESUMO

The creation of multiarticulated mechanisms for use with minimally invasive surgical tools is difficult because of fabrication, assembly, and actuation challenges on the millimeter scale of these devices. Nevertheless, such mechanisms are desirable for granting surgeons greater precision and dexterity to manipulate and visualize tissue at the surgical site. Here, we describe the construction of a complex optoelectromechanical device that can be integrated with existing surgical tools to control the position of a fiber-delivered laser. By using modular assembly and a laminate fabrication method, we are able to create a smaller and higher-bandwidth device than the current state of the art while achieving a range of motion similar to existing tools. The device we present is 6 millimeters in diameter and 16 millimeters in length and is capable of focusing and steering a fiber-delivered laser beam at high speed (1.2-kilohertz bandwidth) over a large range (over ±10 degrees in both of two axes) with excellent static repeatability (200 micrometers).


Assuntos
Terapia a Laser/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Desenho de Equipamento , Humanos , Lasers , Fenômenos Mecânicos , Microtecnologia , Fibras Ópticas , Fenômenos Ópticos , Amplitude de Movimento Articular , Instrumentos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...